Updated: 2025-11-28 20:00 CET
| Basic data | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | STCSA | |||||||||||||||||
| Old ISKO number: | 1771 | |||||||||||||||||
| Locality: | Tobolka-Certovy schody | |||||||||||||||||
| Type of measuring programme: | Automated measuring program | |||||||||||||||||
| Measuring networks: | EUROAIRNET | |||||||||||||||||
| Administrator | ||||||||||||||||||
|
ČHMÚ - Libuš CLI
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | |||||||||||||||||
| E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||
| Target of the measuring programme | ||||||||||||||||||
| Usage for operational management and regulation (SRVS), Evaluation of the significant sources effect on air pollution level | ||||||||||||||||||
| Cover | ||||||||||||||||||
| container (air-conditioned) | ||||||||||||||||||
| Note | ||||||||||||||||||
| Measurements | ||||||||||||||||||
| Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
| L1 | D1 | 61 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | N | N | A | N | R | N | 1h | 2008-11-11 | |
| L1 | D1 | 61 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | N | N | A | N | R | N | 1h | 2008-11-11 | |
| L1 | D1 | 61 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg∙m -3 | Yes | Yes | 0 | N | N | A | N | R | N | 1h | 2008-11-11 | |
| L1 | D1 | 61 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg∙m -3 | Yes | Yes | 0 | N | A | A | N | R | N | 1h | 2008-11-11 | |
| L1 | D1 | 96 | O₃ [ozone] | - | UVABS [UV-absorption] | µg∙m -3 | Yes | Yes | 0 | Y | A | A | A | R | A | 1h | 2011-06-01 | |
| L1 | D1 | 25 | PM₂.₅ [fine particles PM2.5] | - | RADIO [radiometry - beta ray absorption] | µg∙m -3 | Yes | Yes | 0 | N | N | A | A | A | A | 1h | 2008-11-11 | |
| L1 | D1 | 35 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| L1 | D1 | 35 | WV [wind velocity] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2008-11-11 | |
| L1 | D1 | 35 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| L1 | D1 | 35 | WD [wind direction] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2008-11-11 | |
| L1 | D1 | 35 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| L1 | D1 | 35 | WVm [short-term wind velocity maximum] | - | U-SONIC [ultrasonic anemometer] | m/s | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2008-11-11 | |
| L1 | D1 | 35 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| L1 | D1 | 35 | WDm [short-term wind direction maximum] | - | U-SONIC [ultrasonic anemometer] | deg | Yes | Yes | 0 | N | N | A | N | N | N | 10min | 2008-11-11 | |
| L1 | D1 | 60 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| L1 | D1 | 60 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | Yes | Yes | 0 | N | N | A | N | N | N | 1h | 2008-11-11 | |
| List of laboratories | ||||||||||||||||||
| Laboratory number 1 (L1) |
ČHMÚ-CLI TK
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | ||||||||||||||||
| E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||
| List of data suppliers | ||||||||||||||||||
| Supplier number 1 (D1) |
ČHMÚ - Libuš AIM
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244 033 467 | ||||||||||||||||
| E-mail: jan.silhavy@chmi.cz | ||||||||||||||||||