Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: MOLOA
Old ISKO number: 1893
Locality: Olomouc
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
container (air-conditioned)
Note
Dobrá lokalita v sportovním areálu. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - No No 0 N N N N N N 30min 1994-01-26 2003-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes No 0 Y N N N N N 10min 2004-01-01 2007-03-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-26 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-26 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - No No 0 N N N N N N 30min 1994-01-26 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] - No No 0 N N N N N N 30min 1994-05-11 2002-12-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 2003-07-11 2003-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1995-10-21 2003-12-31
L1 D1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] - No No 0 N N N N N N 30min 1994-01-26 1995-10-20
L1 D1 28 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 28 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 28 EBZN [ethylbenzene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 28 MPXY [m,p-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 28 OXY [o-xylene] - GC-FID [gas chromatography - flame-ionization detection] - Yes No 0 Y N N N N N 1h 2004-01-01 2007-03-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 1h 2004-01-01 2007-03-31
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-01-01 2003-07-10
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2003-07-11 2003-12-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 10min 2004-01-01 2007-03-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 1h 2004-01-01 2007-03-31
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 30min 1995-01-01 2003-07-10
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 30min 2003-07-11 2003-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 10min 2004-01-01 2007-03-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 1h 2004-01-01 2007-03-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 10min 2004-01-01 2007-03-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 1h 2004-01-01 2007-03-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - No No 0 N N N N N N 10min 2004-01-01 2007-03-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 30min 1995-01-13 1995-12-31
L1 D1 45 h [relative air humidity (h. of air)] - SKIN [animal skin] - No No 0 N N N N N N 30min 1995-01-13 1995-12-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 1h 2004-01-01 2007-03-31
L1 D1 40 T2m [temperature 2m above terrain] - PT100 [resistance method] - No No 0 N N N N N N 30min 1995-01-13 2003-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava - Poruba
Tel.: 596 900 228
 
E-mail: ooco_ova@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava-Poruba
Tel.: 596 900 239
 
E-mail: ooco_ova@chmi.cz