Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: JKOS0
Old ISKO number: 1557
Locality: Kosetice
Type of measuring programme: Heavy metal in PM10
Measuring networks: National air pollution monitoring network , EMEP
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground
Cover
measuring box (heated)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 55 PM₁₀ [particles PM10] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GRV [gravimetry] µg/m³ Yes No 0 Y A A A R A 1d/2d 2004-01-01
L1 D2 55 V [vanadium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 N A A A R A 1d/2d 2004-01-01
L1 D2 55 Fe [iron] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Co [cobalt] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A R A 1d/2d 2004-01-01
L1 D2 55 Cu [copper] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 N A A A R A 1d/2d 2004-01-01
L1 D2 55 Zn [zinc] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A R A 1d/2d 2004-01-01
L1 D2 55 Se [selenium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A R A 1d/2d 2004-01-01
L1 D2 55 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A R A 1d/2d 2004-01-01
L1 D3 0 PM₁₀ [particles PM10] - GRV [gravimetry] µg/m³ No No 0 N N N N N N 1d/6d 2003-01-01 2003-05-15
L1 D3 0 PM₁₀ [particles PM10] - GRV [gravimetry] µg/m³ Yes No 0 N N N N N N 1d/4d 2003-05-13 2003-12-31
L1 D3 9 PM₁₀ [particles PM10] - GRV [gravimetry] µg/m³ Yes No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 9 Mn [manganese] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 9 Ni [nickel] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 9 Cu [copper] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 0 As [arsenic] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 1d/6d 2003-01-01 2003-05-15
L1 D3 0 As [arsenic] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N N N N N 1d/4d 2003-05-13 2003-12-31
L1 D3 9 As [arsenic] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 0 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 1d/6d 2003-01-01 2003-05-15
L1 D3 0 Cd [cadmium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N N N N N 1d/4d 2003-05-13 2003-12-31
L1 D3 9 Cd [cadmium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L1 D3 0 Pb [lead] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 1d/6d 2003-01-01 2003-05-15
L1 D3 0 Pb [lead] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N N N N N 1d/4d 2003-05-13 2003-12-09
L1 D3 9 Pb [lead] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 1 Y N N N N N 1d/2d 2007-01-01 2010-07-19
L2 D4 9 Hg [mercury] - AMA [Atomic absorption spectrofotometry AMA for mercury determination] ng/m³ No No 0 N N N N N N 7d 2006-09-01 2013-04-30
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Laboratory number 2 ALS Czech Republic, s.r.o.
Na Harfě 9/336
190 00 Praha 9
Tel.: 284 081 600
 
E-mail: pavel.bransky@alsglobal.com
List of data suppliers
Supplier number 1 CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 484
 
E-mail: lucie.sedlakova@chmi.cz
Supplier number 2
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 488
 
E-mail: eliska.svobodova@chmi.cz
Supplier number 3 ČHMÚ-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 482
 
E-mail: stepan.rychlik@chmi.cz
Supplier number 4 CHMI-Kosetice

39422 Košetice
Tel.: 565301052
 
E-mail: jaroslav.pekarek@chmi.cz