Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-02-21 03:46 CET


Basic data
Code: BBNDA
Old ISKO number: 1545
Locality: Brno-stred
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
CHMI - pob.Brno
Kroftova 43
61667 Brno
Tel.: 541421046
 
E-mail: jachym.brzezina@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
not defined
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 N N N N N N 1h 2004-11-01 2008-08-01
1 1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 N N N N N N 10min 2004-11-01 2008-08-01
1 1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2013-12-31
1 1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2013-12-31
1 1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2013-12-31
1 1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-16 2013-12-31
1 1 22 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes No 0 N N N N N N 1h 2004-11-01 2009-12-31
1 1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2013-12-31
1 1 28 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2012-12-31
1 1 28 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 A N N N N N 1h 2004-11-01 2012-12-31
1 1 28 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 N N N N N N 1h 2004-11-01 2009-12-31
1 1 28 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 N N N N N N 1h 2004-11-01 2009-12-31
1 1 28 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 N N N N N N 1h 2004-11-01 2009-12-31
1 1 35 WV [wind velocity] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 1h 2004-11-01 2013-12-31
1 1 35 WV [wind velocity] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 10min 2004-11-01 2013-12-31
1 1 35 WD [wind direction] - OPEL [optoelectronic method] deg No Yes 0 N N N N N N 1h 2004-11-01 2013-12-31
1 1 35 WD [wind direction] - OPEL [optoelectronic method] deg No Yes 0 N N N N N N 10min 2004-11-01 2013-12-31
1 1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 1h 2006-01-01 2013-12-31
1 1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 10min 2009-10-08 2013-12-31
1 1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg No Yes 0 N N N N N N 1h 2006-01-01 2013-12-31
1 1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg No Yes 0 N N N N N N 10min 2009-10-08 2013-12-31
1 1 0 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No No 0 N N N N N N 1h 2010-04-01 2013-12-31
1 1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 1h 2010-04-01 2013-12-31
List of laboratories
Laboratory number 1 CHMI-pob.Brno-AMS
Kroftova 43
61667 Brno
Tel.: 541421044
 
E-mail: zuzana.vranova@chmi.cz
List of data suppliers
Supplier number 1 CHMI-Brno AIM
Kroftova 43
61667 Brno
Tel.: 541421046
 
E-mail: jachym.brzezina@chmi.cz