Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: ASUCA
Old ISKO number: 1528
Locality: Praha 6-Suchdol
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna v areálu ČSAV na travnaté ploše. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-10-01
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 Y N A A A A 1h 2004-10-22
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2004-10-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2004-10-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2004-10-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2004-10-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes No 0 N N A N N N 1h 2004-10-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2004-10-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2004-10-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2004-10-01
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2004-10-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 1h 2005-08-01
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 10min 2005-08-01
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-10-01
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-10-01 2015-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N N N N N 10min 2004-10-01 2015-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-10-01 2015-12-31
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N A A N N N 1h 2020-02-20 2020-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-10-01 2015-12-31
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N A A N N N 1h 2020-02-20 2020-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-11-01 2015-12-31
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes No 0 N A A N N N 1h 2020-02-20 2020-12-31
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 