Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-10-11 04:49 CEST
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | VSKOA | |||||||||||||||||
Old ISKO number: | 1429 | |||||||||||||||||
Locality: | Sniezne Kotly | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | BLACK TRIANGLE | |||||||||||||||||
Administrator | ||||||||||||||||||
Zaklad Ochrony Srodowiska ATMON
Ul. Wolnosci 150 JELENIA GORA |
Tel.: +4875 7526082 | |||||||||||||||||
E-mail: | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Evalution of total level of concentrations beckground, Evaluation of the effect on the population health | ||||||||||||||||||
Cover | ||||||||||||||||||
container (air-conditioned) | ||||||||||||||||||
Note | ||||||||||||||||||
Vrcholová stanice, bez vegetace, bez dopravy. | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 68 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-12-31 |
L1 | D1 | 68 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 2004-01-01 |
L1 | D1 | 69 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-12-31 |
L1 | D1 | 69 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 2004-01-01 |
L1 | D1 | 69 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-12-31 |
L1 | D1 | 69 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 2004-01-01 |
L1 | D1 | 69 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2005-01-01 | 2010-12-31 |
L1 | D1 | 69 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 1997-12-31 |
L1 | D1 | 23 | O₃ [ozone] | - | UVABS [UV-absorption] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-12-31 |
L1 | D1 | 23 | O₃ [ozone] | - | UVABS [UV-absorption] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 2004-01-01 |
L1 | D1 | 0 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2004-12-31 |
L1 | D1 | 0 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1997-01-01 | 2003-12-31 |
L1 | D1 | 0 | WV [wind velocity] | - | ELMAG [electromagnetic method] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2006-01-01 | 2006-12-31 |
L1 | D1 | 0 | WV [wind velocity] | - | ELMAG [electromagnetic method] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1998-01-01 | 2003-12-31 |
L1 | D1 | 0 | WD [wind direction] | - | OPEL [optoelectronic method] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2006-01-01 | 2006-12-31 |
L1 | D1 | 0 | WD [wind direction] | - | OPEL [optoelectronic method] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1998-01-01 | 2003-12-31 |
L1 | D1 | 0 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2004-01-01 | 2010-12-31 |
L1 | D1 | 0 | T [temperature (unspecificated)] | - | PT100 [resistance method] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2006-01-01 | 2006-12-31 |
L1 | D1 | 0 | T [temperature (unspecificated)] | - | PT100 [resistance method] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1998-01-01 | 2003-12-31 |
L1 | D1 | 0 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2006-01-01 | 2006-12-31 |
L1 | D1 | 0 | GLRD [global radiation] | - | TDM [temperature difference method] | - | No | No | 0 | N | N | N | N | N | N | 1h | 2006-01-01 | 2006-12-31 |
L1 | D1 | 0 | GLRD [global radiation] | - | TDM [temperature difference method] | - | No | No | 0 | N | N | N | N | N | N | 30min | 1998-01-01 | 2003-12-31 |
List of laboratories | ||||||||||||||||||
Laboratory number 1 (L1) |
Zaklad Ochrony Srodowiska ATMON
Ul. Wolnosci 150 JELENIA GORA |
Tel.: +4875 7526082 | ||||||||||||||||
E-mail: | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 (D1) |
SWIOS' Jelenia Góra
Ul. Warszavska 28 Jelenia Góra |
Tel.: +4875 7649445 | ||||||||||||||||
E-mail: |