Information about air quality in the Czech Republic
Measuring programme table
Updated: 2016-01-05 03:19 CET
| Basic data | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | TTRE0 | |||||||||||||||||
| Old ISKO number: | 2084 | |||||||||||||||||
| Locality: | Trebom | |||||||||||||||||
| Type of measuring programme: | Heavy metal in PM10 | |||||||||||||||||
| Measuring networks: | ||||||||||||||||||
| Administrator | ||||||||||||||||||
| ČHMÚ - pob.Ostrava K Myslivně 3/2182 70800 Ostrava - Poruba |
Tel.: 596 900 218 | |||||||||||||||||
| Fax:.: 596 910 284 | ||||||||||||||||||
| E-mail: cernikov@chmi.cz | ||||||||||||||||||
| Target of the measuring programme | ||||||||||||||||||
| Cover | ||||||||||||||||||
| measuring box (heated) | ||||||||||||||||||
| Note | ||||||||||||||||||
| Measurements | ||||||||||||||||||
| Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
| 1 | 1 | 8 | V [vanadium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Cr [chromium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Mn [manganese] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Fe [iron] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Co [cobalt] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Ni [nickel] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | Yes | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Cu [copper] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Zn [zinc] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | As [arsenic] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | Yes | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Se [selenium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | No | No | 0 | No | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Cd [cadmium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | Yes | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| 1 | 1 | 8 | Pb [lead] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m3 | Yes | No | 0 | Yes | No | No | No | No | No | 1d/6d | 2016-01-01 | |
| List of laboratories | ||||||||||||||||||
| Laboratory number 1 | ČHMÚ-CLI TK Gen.Šišky 942 143 00 Praha 4 - Libuš |
Tel.: 244033451 | ||||||||||||||||
| Fax:.: | ||||||||||||||||||
| E-mail: novakj@chmi.cz | ||||||||||||||||||
| List of data suppliers | ||||||||||||||||||
| Supplier number 1 | ČHMÚ-CLI TK Generála Šišky 942 14300 Praha 4 - Libuš |
Tel.: 244033482 | ||||||||||||||||
| Fax:.: | ||||||||||||||||||
| E-mail: rychliks@chmi.cz | ||||||||||||||||||
ISKO