Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-02-21 03:46 CET


Basic data
Code: TOPR0
Old ISKO number: 1542
Locality: Ostrava-Privoz
Type of measuring programme: Heavy metal in PM10
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
sampler (situated separately)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 55 V [vanadium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
1 1 55 Cr [chromium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
1 1 55 Mn [manganese] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 N A A A R A 1d/2d 2004-01-01
1 1 55 Fe [iron] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
1 1 55 Co [cobalt] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
1 1 55 Ni [nickel] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 A A A A R A 1d/2d 2004-01-01
1 1 55 Cu [copper] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 N A A A R A 1d/2d 2004-01-01
1 1 55 Zn [zinc] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N A A A R A 1d/2d 2011-01-01
1 1 55 As [arsenic] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 A A A A R A 1d/2d 2004-01-01
1 1 55 Se [selenium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ No No 0 N N A A R A 1d/2d 2011-01-01
1 1 55 Cd [cadmium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 A A A A R A 1d/2d 2004-01-01
1 1 55 Pb [lead] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 A A A A R A 1d/2d 2004-01-01
1 2 55 PM₁₀ [particles PM10] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] µg/m³ Yes No 0 A A A A R A 1d/2d 2004-01-01 2022-01-01
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 488
 
E-mail: eliska.svobodova@chmi.cz
Supplier number 2 CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 484
 
E-mail: lucie.sedlakova@chmi.cz