Updated: 2025-11-28 20:00 CET
| Basic data | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | TOMH0 | |||||||||||||||||
| Old ISKO number: | 1750 | |||||||||||||||||
| Locality: | Ostrava-Marianske Ho | |||||||||||||||||
| Type of measuring programme: | Heavy metal in PM10 | |||||||||||||||||
| Measuring networks: | ||||||||||||||||||
| Administrator | ||||||||||||||||||
|
ZU-Ostrava
Partyzánské nám. 7 702 00 Ostrava 1 |
Tel.: 596 200 361 | |||||||||||||||||
| E-mail: lucie.hellebrandova@zuova.cz | ||||||||||||||||||
| Target of the measuring programme | ||||||||||||||||||
| Evalution of concentration in urban areas | ||||||||||||||||||
| Cover | ||||||||||||||||||
| container (air-conditioned) | ||||||||||||||||||
| Note | ||||||||||||||||||
| Measurements | ||||||||||||||||||
| Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
| L1 | D1 | 55 | Cr [chromium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| L1 | D1 | 55 | Mn [manganese] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| L1 | D1 | 55 | Ni [nickel] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| L1 | D1 | 55 | As [arsenic] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| L1 | D1 | 55 | Cd [cadmium] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| L1 | D1 | 55 | Pb [lead] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | ICP-MS [inductively coupled plasma - mass spectrometry] | ng/m³ | Yes | No | 0 | Y | A | A | A | N | A | 14d | 2018-01-01 | |
| List of laboratories | ||||||||||||||||||
| Laboratory number 1 (L1) |
KHS-Ostrava
Partyzánské náměstí 7 702 00 Ostrava 1 |
Tel.: 596 200 361 | ||||||||||||||||
| E-mail: lucie.hellebrandova@zuova.cz | ||||||||||||||||||
| List of data suppliers | ||||||||||||||||||
| Supplier number 1 (D1) |
KHS-Ostrava
Partyzánské nám. 7 70200 Ostrava 1 |
Tel.: 596 200 375 | ||||||||||||||||
| E-mail: hana.miturova@zuova.cz | ||||||||||||||||||