Updated: 2025-11-28 20:00 CET
| Basic data | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | SNYMP | |||||||||||||||||
| Old ISKO number: | 2397 | |||||||||||||||||
| Locality: | Nymburk | |||||||||||||||||
| Type of measuring programme: | Measuring program of PAHs | |||||||||||||||||
| Measuring networks: | ||||||||||||||||||
| Administrator | ||||||||||||||||||
|
ČHMÚ - Libuš CLI
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | |||||||||||||||||
| E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||
| Target of the measuring programme | ||||||||||||||||||
| Cover | ||||||||||||||||||
| without shelter | ||||||||||||||||||
| Note | ||||||||||||||||||
| Measurements | ||||||||||||||||||
| Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
| L1 | D1 | 55 | BaA [benzo(a)anthracene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | Chry [chrysene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | BbF [benzo(b)fluoranthene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | BjF [benzo(j)fluoranthene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | BkF [benzo(k)fluoranthene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | B[𝑎]P [benzo[a]pyrene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | I123cdP [indeno(1,2,3,-cd) pyrene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | DBahA [dibenzo(a,h)anthracene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| L1 | D1 | 55 | BghiPRL [benzo(g,h,i) perylene] | LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] | HPLC-FL [High perfomace liquid chromatography with fluorescence detector] | ng/m³ | Yes | No | 0 | Y | A | A | N | R | A | 1d/6d | 2021-01-05 | 2022-01-03 |
| List of laboratories | ||||||||||||||||||
| Laboratory number 1 (L1) |
ČHMÚ-CLI TK
Gen.Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244033451 | ||||||||||||||||
| E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||
| List of data suppliers | ||||||||||||||||||
| Supplier number 1 (D1) |
CMHU-CLI
Generála Šišky 942 143 00 Praha 4 - Kamýk |
Tel.: 244 033 451 | ||||||||||||||||
| E-mail: stepan.rychlik@chmi.cz | ||||||||||||||||||