Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: SKLS0
Old ISKO number: 1616
Locality: Kladno-Svermov
Type of measuring programme: Heavy metal in PM10
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Cover
without shelter
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 55 PM₁₀ [particles PM10] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GRV [gravimetry] - Yes No 0 Y A A A R A 1d/2d 2006-01-01
L1 D2 55 V [vanadium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N A A A R A 1d/2d 2006-01-01
L1 D2 55 Fe [iron] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Co [cobalt] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2006-01-01
L1 D2 55 Cu [copper] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 N A A A R A 1d/2d 2006-01-01
L1 D2 55 Zn [zinc] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N A A A R A 1d/2d 2011-01-01
L1 D2 55 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2006-01-01
L1 D2 55 Se [selenium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - No No 0 N N A A R A 1d/2d 2011-01-01
L1 D2 55 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2006-01-01
L1 D2 55 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] - Yes No 0 Y A A A R A 1d/2d 2006-01-01
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 484
 
E-mail: lucie.sedlakova@chmi.cz
Supplier number 2 (D2)
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244 033 488
 
E-mail: eliska.svobodova@chmi.cz