Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-02-28 03:43 CET


Basic data
Code: PPLLA
Old ISKO number: 1324
Locality: Plzen-Lochotin
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
Správa infrastruktury města Plzně
Dominikánská 4
301 00 Plzeň
Tel.: 378035136
 
E-mail:
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
V kontejneru na volném prostranství mezi bloky zástavby sídlištního typu. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N A N N N 1h 2004-01-01
1 1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N A N N N 10min 2004-01-01
1 1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 96 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 88 PM 1 [fine particles PM1] - OPEL [optoelectronic method] µg/m³ No Yes 0 N N N N N N 1h 2010-03-01
1 1 88 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] µg/m³ Yes Yes 0 N N A A A A 1h 2010-03-01
1 1 88 PM₁₀ [particles PM10] - OPEL [optoelectronic method] µg/m³ Yes Yes 0 N N A A A A 1h 2010-03-01
1 1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2006-11-16
1 1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2006-11-16
1 1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2006-11-16
1 1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2006-11-16
1 1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2006-11-16
1 1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2004-11-05
1 1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2006-11-16
1 1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2004-11-05
1 1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2004-01-01
1 1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-01-01
1 1 41 T10m [temperature 10m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-01-01
1 1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 22 O₃ [ozone] - UVABS [UV-absorption] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 1h 2004-01-01 2010-02-28
1 1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 37 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 1h 2004-01-01 2006-11-16
1 1 37 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 37 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 10min 2004-01-01 2006-11-16
1 1 37 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 1h 2004-01-01 2006-11-16
1 1 37 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 37 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 10min 2004-01-01 2006-11-16
1 1 37 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 1h 2004-01-01 2006-11-16
1 1 37 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg No No 0 N N N N N N 1h 2004-01-01 2006-11-16
1 1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 30min 1996-01-05 2003-12-31
1 1 41 T10m [temperature 10m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 30min 1996-01-05 2003-12-31
List of laboratories
Laboratory number 1 ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz