Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: MOLS0
Old ISKO number: 1692
Locality: Olomouc-Smeralova
Type of measuring programme: Heavy metal in PM10
Measuring networks:
Administrator
ZU-Ostrava
Partyzánské nám. 7
702 00 Ostrava 1
Tel.: 596 200 361
 
E-mail: lucie.hellebrandova@zuova.cz
Target of the measuring programme
Evaluation of the effect on the population health
Cover
measuring box (heated)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 7 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L1 D1 7 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L1 D1 7 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L1 D1 7 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L1 D1 7 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L1 D1 7 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y A A A N A 14d 2001-07-01
L2 D1 0 Cr [chromium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 2001-06-30
L2 D1 0 Cr [chromium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
L2 D1 0 Mn [manganese] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 2000-01-01 2001-06-30
L2 D1 0 Ni [nickel] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 2001-06-30
L2 D1 0 Ni [nickel] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
L2 D1 0 Zn [zinc] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 1999-12-31
L2 D1 0 Zn [zinc] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
L2 D1 0 As [arsenic] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 2001-06-30
L2 D1 0 As [arsenic] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
L2 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 2001-06-30
L2 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
L2 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 14d 1998-01-01 2001-06-30
L2 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] ng/m³ No No 0 N N N N N N 7d 1996-01-01 1997-12-31
List of laboratories
Laboratory number 1 KHS-Ostrava
Partyzánské náměstí 7
702 00 Ostrava 1
Tel.: 596 200 361
 
E-mail: lucie.hellebrandova@zuova.cz
Laboratory number 2 ZU se sidlem v Ostravě-CHL
Wolkerova 6
77900 Olomouc
Tel.: 703 552 400
 
E-mail: radko.hradil@zuova.cz
List of data suppliers
Supplier number 1 ZU se sidlem v Ostravě-CHL
Wolkerova 6
77900 Olomouc
Tel.: 703 552 400
 
E-mail: radko.hradil@zuova.cz