Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-10-11 04:49 CEST


Basic data
Code: KCHMA
Old ISKO number: 1506
Locality: Cheb
Type of measuring programme: Automated measuring program
Measuring networks: AMS-SRS, National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] - Yes Yes 0 Y N A A A A 1h 2004-12-15
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-02-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-02-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-02-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-02-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-02-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-02-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 1h 2006-02-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] - Yes Yes 0 N N A N N N 10min 2006-02-01
L1 D1 74 T2m [temperature 2m above terrain] - PT100 [resistance method] - Yes Yes 0 N N A N N N 1h 2004-12-15
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 1h 2004-12-15 2012-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] - Yes Yes 0 Y N N N N N 10min 2004-12-15 2012-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-12-15 2012-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-12-15 2012-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] - Yes Yes 0 Y N N N N N 1h 2004-12-15 2012-12-31
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-12-15 2006-01-31
L1 D1 38 WV [wind velocity] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-12-15 2006-01-31
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-12-15 2006-01-31
L1 D1 38 WD [wind direction] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-12-15 2006-01-31
L1 D1 38 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-12-15 2006-01-31
L1 D1 38 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-12-15 2006-01-31
L1 D1 38 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 1h 2004-12-15 2006-01-31
L1 D1 38 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] - No No 0 N N N N N N 10min 2004-12-15 2006-01-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] - No No 0 N N N N N N 1h 2007-01-01 2009-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] - No Yes 0 N N N N N N 1h 2004-12-15 2013-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No Yes 0 N N N N N N 1h 2004-12-15 2013-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] - No Yes 0 N N N N N N 10min 2004-12-15 2013-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 