Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-02-21 03:46 CET


Basic data
Code: CCBDA
Old ISKO number: 1104
Locality: Ceske Budejovice
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Kontejner umístěn na travnatém prostranství mezi městskou zástavbou, asi 300m od pravého břehu Vltavy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 A A A A R A 10min 2004-01-01
1 1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 96 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 A A A A R A 1h 2004-01-01
1 1 25 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 A N A A A A 1h 2004-01-01
1 1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 A N A A A A 1h 2004-01-01
1 1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2004-11-01
1 1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2004-11-01
1 1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2004-11-01
1 1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2004-11-01
1 1 97 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes No 0 N N A N N N 1h 2015-05-15
1 1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes No 0 N N A N N N 10min 2015-05-15
1 1 97 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-11-01
1 1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 N N N N N N 30min 1994-03-28 2003-12-31
1 1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1994-03-28 2003-12-31
1 1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1994-03-28 2003-12-31
1 1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1994-03-28 2003-12-31
1 1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes No 0 A N N N N N 1h 2004-01-01 2009-01-13
1 1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes No 0 N N N N N N 30min 1994-09-07 2003-12-31
1 1 22 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes No 0 N N N N N N 30min 1994-09-07 2003-12-31
1 1 26 PM₂.₅ [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 2003-05-01 2003-12-31
1 1 24 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes No 0 N N N N N N 30min 1995-10-24 2003-12-31
1 1 24 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 1994-03-28 1995-10-23
1 1 28 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 A N N N N N 1h 2004-01-01 2012-12-31
1 1 28 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 A N N N N N 1h 2004-01-01 2012-12-31
1 1 28 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 A N N N N N 1h 2004-01-01 2009-12-31
1 1 28 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 A N N N N N 1h 2004-01-01 2009-12-31
1 1 28 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 A N N N N N 1h 2004-01-01 2009-12-31
List of laboratories
Laboratory number 1 ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz