Information about air quality in the Czech Republic

Measuring programme table

Updated: 2022-11-15 08:08 CET


Basic data
Code: AVRSA
Old ISKO number: 805
Locality: Praha 10-Vrsovice
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna v areálu mateřské školy, asi 15m od hlavní komunikace. 11.7.2003 výměna Verewa za FH62, sonda Kalmán za Anderson.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2020-01-10
1 1 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2020-01-10
1 1 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 A A A A R A 1h 2020-01-10
1 1 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 A N A A A A 1h 2004-01-01
1 1 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
1 1 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N N N N N 10min 2004-11-29 2012-12-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
1 1 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
1 1 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 1992-02-01 2003-12-31
1 1 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes No 0 N N N N N N 30min 1995-10-01 2003-12-31
1 1 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 1992-02-01 1995-10-31
1 1 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 30min 1992-02-01 1999-08-31
1 1 T [temperature (unspecificated)] - PT100 [resistance method] K No No 0 N N N N N N 30min 1996-01-01 1999-08-31
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 