Information about air quality in the Czech Republic

Measuring programme table

Updated: 2019-04-12 08:57 CEST


Basic data
Code: USTEA
Old ISKO number: 2248
Locality: Steti
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
Fax:.:
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 A N A N R N 1h 2018-01-01
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 A N A N R N 10min 2018-01-01
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2018-01-01
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2018-01-01
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2018-01-01
1 1 O3 [ozone] - UVABS [UV-absorption] µg/m3 Yes Yes 0 A N A N R N 1h 2018-01-01
1 1 PM1 [fine particles PM1] - OPEL [optoelectronic method] µg/m3 Yes Yes 0 N N N A R A 1h 2018-01-01
1 1 PM2,5 [fine particles PM2.5] - OPEL [optoelectronic method] µg/m3 Yes Yes 0 N N N A R A 1h 2018-01-01
1 1 PM10 [particles PM10] - OPEL [optoelectronic method] µg/m3 Yes Yes 0 N N N A R A 1h 2018-01-01
1 1 H2S [(sulphuretted hydrogen) hydrogen sulphide] - UVFL [UV-fluorescence] µg/m3 No Yes 0 N N A N N N 1h 2018-01-01
1 1 H2S [(sulphuretted hydrogen) hydrogen sulphide] - UVFL [UV-fluorescence] µg/m3 No Yes 0 N N A N N N 10min 2018-01-01
1 1 TRS [total reduced sulphur] - UVFL [UV-fluorescence] µg/m3 No Yes 0 N N A N N N 1h 2018-01-01
1 1 TRS [total reduced sulphur] - UVFL [UV-fluorescence] µg/m3 No Yes 0 N N A N N N 10min 2018-01-01
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 1h 2018-01-01
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 10min 2018-01-01
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2018-01-01
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2018-01-01
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 1h 2018-01-01
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 10min 2018-01-01
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N A N N N 1h 2018-01-01
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2018-01-01
1 1 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No Yes 0 N N N N N N 1h 2018-01-01
1 1 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2018-01-01
1 1 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] mm No Yes 0 N N N N N N 1h 2018-01-01
1 1 RAIN [precipitation amount (rain am.)] - RAIN [standard rain gauge] mm No Yes 0 N N N N N N 10min 2018-01-01
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 1h 2018-01-01
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 10min 2018-01-01
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2018-01-01
List of laboratories
Laboratory number 1 CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
Fax:.:
E-mail: petr.goll@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 050
Fax:.:
E-mail: petra.mrazova@chmi.cz