Information about air quality in the Czech Republic

Measuring programme table

Updated: 2019-04-12 08:58 CEST


Basic data
Code: JZNZ0
Old ISKO number: 1683
Locality: Zdar nad Sazavou
Type of measuring programme: Heavy metal in PM10
Measuring networks:
Administrator
ZU-Ostrava
Partyzánské nám. 7
702 00 Ostrava 1
Tel.: 596 200 361
Fax:.: 596 118 661
E-mail: lucie.hellebrandova@zuova.cz
Target of the measuring programme
Evalution of total level of concentrations beckground
Cover
measuring box (heated)
Note
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
1 1 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
1 1 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
1 1 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
1 1 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
1 1 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A N A 14d 2015-01-01
2 2 Cr [chromium] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-05 2014-12-31
2 2 Cr [chromium] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
2 2 Mn [manganese] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 2000-01-03 2014-12-31
2 2 Ni [nickel] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-05 2014-12-31
2 2 Ni [nickel] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
2 2 Zn [zinc] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-01 1999-12-31
2 2 Zn [zinc] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
2 2 As [arsenic] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-05 2014-12-31
2 2 As [arsenic] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
2 2 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-05 2014-12-31
2 2 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
2 2 Pb [lead] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 14d 1998-01-05 2014-12-31
2 2 Pb [lead] - AAS [atomic absorption spectrometry] ng/m3 No No 0 N N N N N N 7d 1996-01-01 1997-12-31
List of laboratories
Laboratory number 1 KHS-Ostrava
Partyzánské náměstí 7
70200 Ostrava 1
Tel.: 596 200 361
Fax:.: 596 118 661
E-mail: lucie.hellebrandova@zuova.cz
Laboratory number 2 ZU-Ostrava, prac. Jihlava
Vrchlického 57
587 25 Jihlava
Tel.: 567 574 775
Fax:.: 567 757 771
E-mail: jindrich.rosecky@zuova.cz
List of data suppliers
Supplier number 1 ZU-Ostrava, prac. Jihlava
Vrchlického 57
587 25 Jihlava
Tel.: 604 457 958
Fax:.: 567 757 771
E-mail: martin.klouda@zuova.cz
Supplier number 2 ZU- Ostrava, prac. Jihlava
Vrchlického 57
587 25 Jihlava
Tel.: 567 574 775
Fax:.: 567 767 771