Information about air quality in the Czech Republic
Measuring programme table
Updated: 2014-06-03 15:41 CEST
| Basic data | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | ULPRA | ||||||||||
| Old ISKO number: | 1575 | ||||||||||
| Locality: | Libkovice pod Ripem | ||||||||||
| Type of measuring programme: | Automated measuring program | ||||||||||
| Measuring networks: | |||||||||||
| Administrator | |||||||||||
| ORGREZ, a.s. Budovatelů 2531 43401 Most |
Tel.: 476702785 | ||||||||||
| Fax:.: 476702785 | |||||||||||
| E-mail: zdenek.chmela@orgrez.cz | |||||||||||
| Target of the measuring programme | |||||||||||
| Cover | |||||||||||
| not defined | |||||||||||
| Note | |||||||||||
| Measurements | |||||||||||
| Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
| 1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2006-01-01 | |
| 1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2006-01-01 | |
| 1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2006-01-01 | |
| 1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2006-01-01 | |
| 1 | 1 | PM10 [particles PM10] | OPTORADIO [opto-radiometric method] | µg/m3 | Yes | No | 0 | Yes | 1h | 2012-04-01 | |
| 1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | No | 0 | No | 1h | 2006-01-01 | |
| 1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | No | 0 | No | 1h | 2006-01-01 | |
| 1 | 1 | T10m [temperature 10m above terrain] | PT100 [resistance method] | K | No | No | 0 | No | 1h | 2006-01-01 | |
| 1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| 1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| 1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| 1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| 1 | 1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| 1 | 1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | No | 30min | 2005-01-01 | 2005-12-31 |
| List of laboratories | |||||||||||
| Laboratory number1 | ORGREZ,a.s.-Zkusebni labor. Most c.1179 Budovatelů 2531 43401 Most |
Tel.: 476702785 | |||||||||
| Fax:.: 476702785 | |||||||||||
| E-mail: jan.pomahac@orgrez.cz | |||||||||||
| List of data suppliers | |||||||||||
| Supplier number1 | ORGREZ,a.s. Budovatelů 2531 43401 Most |
Tel.: 476702785 | |||||||||
| Fax:.: 476702785 | |||||||||||
| E-mail: zdenek.chmela@orgrez.cz | |||||||||||
Tabular Survey 2013