Information about air quality in the Czech Republic

Measuring programme table

Updated: 2014-06-03 15:41 CEST


Basic data
Code: SMBOA
Old ISKO number: 1437
Locality: Mlada Boleslav
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution network
Administrator
ČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz
Target of the measuring programme
Evaluation of the effect on the population health, Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Stanice je umístěna ve sportovním areálu blízko sídliště. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Component Method Unit A R Par. Ac Interval Date of start Date of end
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 1h 2004-01-01
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 10min 2004-01-01
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 1h 2004-01-01
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 10min 2004-01-01
1 1 WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 1h 2004-01-01
1 1 WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 10min 2004-01-01
1 1 WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 1h 2004-01-01
1 1 WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 10min 2004-01-01
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 No 1h 2004-01-01
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 No 1h 2004-01-01
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 No 1h 2005-08-01
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 No 10min 2005-08-01
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 No 1h 2004-01-01
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01 2012-12-31
2 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 No 30min 1998-04-16 2003-12-31
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 Yes 10min 2004-01-01 2012-12-31
2 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1998-04-16 2003-12-31
2 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1998-04-16 2003-12-31
2 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1998-04-16 2003-12-31
1 1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 Yes 1h 2009-04-01 2012-12-31
2 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes No 0 No 30min 2003-03-01 2003-12-31
2 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 No 30min 1998-04-16 2003-12-31
2 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 No 30min 1999-02-24 2003-12-31
2 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 No 30min 1999-02-24 2003-12-31
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 No 1h 2004-01-01 2009-12-31
2 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 No 30min 1999-03-17 2003-12-31
2 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 No 30min 1998-04-16 1999-08-31
2 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 No 30min 1999-02-24 2003-12-31
2 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No No 0 No 30min 1999-04-01 2003-12-31
2 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 No 30min 1999-02-24 2003-12-31
List of laboratories
Laboratory number1 ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz
Laboratory number2 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244033451
Fax:.: 241727935
E-mail: novakj@chmi.cz
List of data suppliers
Supplier number1 ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz