Information about air quality in the Czech Republic

Measuring programme table

Updated: 2014-06-03 15:41 CEST


Basic data
Code: HSERA
Old ISKO number: 1111
Locality: Serlich
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution network, EUROAIRNET, IRIS
Administrator
ČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS), Evalution of total level of concentrations beckground
Cover
container (air-conditioned)
Note
Stanice je umístěna 150m od Masarykovy boudy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Component Method Unit A R Par. Ac Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 Yes 1h 2005-01-01 2011-03-31
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 No 30min 1994-12-21 2004-12-31
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 Yes 10min 2004-01-01 2011-03-31
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2005-01-01 2013-10-24
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-12-21 2004-12-31
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2005-01-01 2013-10-24
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-12-21 2004-12-31
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2005-01-01 2013-10-24
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-12-21 2004-12-31
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 Yes 1h 2005-01-01 2013-10-24
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes No 0 No 30min 1995-08-01 2004-12-31
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 Yes 1h 2005-01-01 2013-10-24
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 No 30min 1996-01-01 2004-12-31
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 No 30min 1995-02-09 1995-12-31
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No No 0 No 30min 2004-01-01 2004-12-31
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 No 10min 2004-01-01 2013-10-24
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No No 0 No 30min 2004-01-01 2004-12-31
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 No 10min 2004-01-01 2013-10-24
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No No 0 No 30min 2004-01-01 2004-12-31
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 No 10min 2004-01-01 2013-10-24
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 No 30min 1997-11-01 2001-11-07
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No No 0 No 30min 2001-11-08 2004-12-31
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 10min 2004-11-01 2013-10-24
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 No 30min 1997-11-01 2001-11-07
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No No 0 No 30min 2001-11-08 2004-12-31
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 10min 2004-11-01 2013-10-24
1 1 WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 1h 2007-01-01 2013-10-24
1 1 WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 10min 2007-01-01 2013-10-24
1 1 WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 1h 2007-01-01 2013-10-24
1 1 WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 No 10min 2007-01-01 2013-10-24
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 No 30min 1997-11-01 1998-12-31
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 No 30min 1999-01-01 2004-12-31
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No No 0 No 30min 1999-01-01 2004-12-31
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 No 30min 1997-11-01 2004-12-31
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 No 10min 2004-12-01 2013-10-24
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 No 1h 2005-01-01 2013-10-24
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 No 30min 1999-01-01 2004-12-31
List of laboratories
Laboratory number1 ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz
List of data suppliers
Supplier number1 ČHMÚ - pob.Hradec Králové
Dvorská 410
50311 Hradec Králové
Tel.: 495 705 040
Fax:.: 495 705 001
E-mail: martina.cerna@chmi.cz