Information about air quality in the Czech Republic

Measuring programme table

Updated: 2013-07-15 16:59 CEST


Basic data
Code: JKOSA
Old ISKO number: 1138
Locality: Kosetice
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET, National air pollution network
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
14200 Praha 4 - Libuš
Tel.: 244033467
Fax:.: 241727935
E-mail: silhavy@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS), Evalution of total level of concentrations beckground
Cover
container (air-conditioned)
Note
Stanice je umístěna v areálu meteorologické stanice ČHMÚ. 12.2.2003 výměna Verewa za FH62 a výměna sondy Kalmán za Digitel DPM10.
Measurements
Lab. Supp. Component Method Unit A R Par. Ac Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 No 10min 2004-01-01
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 PM2,5 [fine particles PM2.5] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 No 1h 2011-01-01
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 No 1h 2004-01-01
1 1 Hg [mercury] AFS [low-temperature gas atomic fluorescence spectrometry] ng/m3 Yes No 0 No 1h 2013-01-01
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 No 30min 1992-12-01 2003-12-31
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1992-12-01 2003-12-31
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1992-12-01 2003-12-31
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1992-12-01 2003-12-31
1 1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes No 0 No 30min 1996-01-01 2003-12-31
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes No 0 No 30min 1992-12-01 2003-12-31
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 No 30min 1995-10-23 2003-12-31
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 No 30min 1992-12-01 1995-10-22
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 No 30min 1993-12-01 1999-08-31
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 No 30min 1996-01-01 1999-08-31
List of laboratories
Laboratory number1 ČHMÚ-CLI TK
Gen.Šišky 942
14300 Praha 4 - Libuš
Tel.: 244033451
Fax:.: 241727935
E-mail: novakj@chmi.cz
List of data suppliers
Supplier number1 ČHMÚ - Libuš AIM
Generála Šišky 942
14000 Praha 4 - Libuš
Tel.: 244033467
Fax:.: 241727935
E-mail: silhavy@chmi.cz