Information about air quality in the Czech Republic

Measuring programme table

Updated: 2012-08-30 10:59 CEST


Basic data
Code: BMISA
Old ISKO number: 1135
Locality: Mikulov-Sedlec
Type of measuring programme: Automated measuring program
Measuring networks: IRIS, National air pollution network
Administrator
ČHMÚ - pob.Brno
Kroftova 43
61667 Brno
Tel.: 541421046
Fax:.: 541421018
E-mail: robert.skeril@chmi.cz
Target of the measuring programme
Data for research, models, verification, etc.
Cover
not defined
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Component Method Unit A R Par. Ac Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 PM2,5 [fine particles PM2.5] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 Yes 1h 2010-01-01
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 BZN [Benzene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 TLN [toluene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes Yes 0 Yes 1h 2004-01-01
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 No 1h 2004-01-01
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 No 1h 2004-01-01
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 No 1h 2004-01-01
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No Yes 0 No 1h 2004-01-01
1 1 WD [wind direction] OPEL [optoelectronic method] deg No Yes 0 No 1h 2004-01-01
1 1 WVm [short-term wind velocity maximum] OPEL [optoelectronic method] m/s No Yes 0 No 1h 2006-01-01
1 1 WDm [short-term wind direction maximum] OPEL [optoelectronic method] deg No Yes 0 No 1h 2006-01-01
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 No 1h 2004-01-01
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 No 1h 2004-01-01
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 No 1h 2004-01-01
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 No 1h 2004-01-01
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes No 0 No 30min 1994-10-01 2003-12-31
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-10-01 2003-12-31
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-10-01 2003-12-31
1 1 NOx [nitrogen oxides] CHLM [chemiluminescence] µg/m3 Yes No 0 No 30min 1994-10-01 2003-12-31
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes No 0 No 30min 1996-03-06 2003-12-31
1 1 PM10 [particles PM10] RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 No 30min 1995-10-21 2003-12-31
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 No 30min 1994-10-01 1995-10-20
1 1 NH3 [ammonia] CHLM [chemiluminescence] µg/m3 Yes Yes 0 No 1h 2004-01-01 2011-05-13
1 1 BZN [Benzene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 TLN [toluene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 EBZN [ethylbenzene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 Yes 1h 2004-01-01 2009-12-31
1 1 EBZN [ethylbenzene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 MPXY [m,p-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 Yes 1h 2004-03-17 2009-12-31
1 1 OXY [o-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 Yes 1h 2004-01-01 2009-12-31
1 1 OXY [o-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 MXY [m-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 1h 2004-01-01 2004-03-16
1 1 MXY [m-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 PXY [p-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 1h 2004-01-01 2004-03-16
1 1 PXY [p-xylene] GC-FID [gas chromatography - flame-ionization detection] µg/m3 Yes No 0 No 30min 1998-04-01 2003-12-31
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 No 30min 1995-01-01 2003-12-31
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 No 30min 1995-01-01 2003-12-31
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 No 1h 2004-01-01 2004-12-31
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 No 30min 1996-06-11 2003-12-31
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 No 30min 1996-01-01 2003-06-19
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 No 30min 1996-01-01 2003-11-23
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 No 30min 1996-01-01 2003-11-23
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 No 30min 2003-10-01 2003-11-23
List of laboratories
Laboratory number1 ČHMÚ-pob.Brno-AMS
Kroftova 43
61667 Brno
Tel.: 541421043
Fax:.:
E-mail: petra.tylichova@chmi.cz
List of data suppliers
Supplier number1
Kroftova 43
61667 Brno
Tel.: 541421046
Fax:.: 541421018
E-mail: robert.skeril@chmi.cz