Information about air quality in the Czech Republic
Measuring programme table
Updated: 2012-08-30 10:59 CEST
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code: | ARIEA | ||||||||||
Old ISKO number: | 772 | ||||||||||
Locality: | Pha2-Riegrovy sady | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | EUROAIRNET, National air pollution network | ||||||||||
Administrator | |||||||||||
ČHMÚ - Libuš CLI Gen.Šišky 942 14200 Praha 4 - Libuš |
Tel.: 244033467 | ||||||||||
Fax:.: 241727935 | |||||||||||
E-mail: silhavy@chmi.cz | |||||||||||
Target of the measuring programme | |||||||||||
Usage for operational management and regulation (SRVS) | |||||||||||
Cover | |||||||||||
container (air-conditioned) | |||||||||||
Note | |||||||||||
Stanice je umístěna na svahu v parku asi 50m od málo frekventované komunikace. 30.11.2000 došlo k výměně prachoměru. Verewa F703V a sondy PM10 Kalman byly nahrazeny prachoměrem FH 62 I-R se sondami PM10 Anderson. Dne 1.6.2004 došlo k výměně prachoměru FH621R se sondou PM10 Anderson za pr achoměr MP101M se sondou Digitel. | |||||||||||
Measurements | |||||||||||
Lab. | Supp. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2010-01-01 | |
1 | 1 | PM2,5 [fine particles PM2.5] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | No | 1h | 2011-01-01 | |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 2004-01-01 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-02-19 | 2003-12-31 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-02-19 | 2003-12-31 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-02-19 | 2003-12-31 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-02-19 | 2003-12-31 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1995-10-20 | 2003-12-31 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1992-02-19 | 1995-10-19 |
1 | 1 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1992-02-19 | 1999-08-31 |
1 | 1 | T [temperature (unspecificated)] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-01-01 | 1999-08-31 |
List of laboratories | |||||||||||
Laboratory number1 | ČHMÚ-CLI TK Gen.Šišky 942 14300 Praha 4 - Libuš |
Tel.: 244033484 | |||||||||
Fax:.: 241727935 | |||||||||||
E-mail: novakj@chmi.cz | |||||||||||
List of data suppliers | |||||||||||
Supplier number1 | ČHMÚ - Libuš AIM Generála Šišky 942 14000 Praha 4 - Libuš |
Tel.: 244033467 | |||||||||
Fax:.: 241727935 | |||||||||||
E-mail: silhavy@chmi.cz |