UMEDA, Medenec

Situation in the year: 2009

Basic data
Code of the measuring programme in the given locality:UMEDA
Old ISKO number:1000
Locality: Medenec
Type of measuring programme: Automated measuring program
Measuring networks:AMS-SRS, National air pollution network 
Address
AdministratorČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
Ing. Miroslav  Bitter   
40011  Ústí n/Labem
Tel:472706053
Fax:472706024
E-mail: bitter@chmi.cz
Supplementary data
Target of the measurement programme:Usage for operational management and regulation (SRVS)
Place description
Na samotě u rekreačního střediska (1.budova) v okolí pole, nízká zeleň, ve vrcholové partii, mírný svah. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesYes0Yes1h01.01.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No1h01.10.2005 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoYes0No10min01.10.2005 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No1h01.10.2005 
11WD [wind direction] OPEL [optoelectronic method]degNoYes0No10min01.10.2005 
11WVm [short-term wind velocity maximum] OPEL [optoelectronic method]m/sNoYes0No1h01.10.2005 
11WVm [short-term wind velocity maximum] OPEL [optoelectronic method]m/sNoYes0No10min01.10.2005 
11WDm [short-term wind direction maximum] OPEL [optoelectronic method]degNoYes0No1h01.10.2005 
11WDm [short-term wind direction maximum] OPEL [optoelectronic method]degNoYes0No10min01.10.2005 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2004 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesNo0No30min04.03.199231.12.2003 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesNo0No30min04.03.199231.12.2003 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesNo0No30min04.03.199231.12.2003 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesNo0No30min04.03.199231.12.2003 
11CO [carbon monoxide] IRABS [IR corel. absorption spectrometry]µg/m3YesNo0No30min23.03.199531.12.2003 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesNo0No30min21.10.199531.12.2003 
11SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min04.03.199220.10.1995 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No1h01.01.200430.09.2005 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No30min05.08.199431.12.2003 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No10min01.01.200430.09.2005 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No1h01.01.200430.09.2005 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No30min05.08.199431.12.2003 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No10min01.01.200430.09.2005 
11WVm [short-term wind velocity maximum] ELMAG [electromagnetic method]m/sNoNo0No1h01.01.200430.09.2005 
11WVm [short-term wind velocity maximum] ELMAG [electromagnetic method]m/sNoNo0No10min01.01.200430.09.2005 
11WDm [short-term wind direction maximum] OPEL [optoelectronic method]degNoNo0No1h01.01.200430.09.2005 
11WDm [short-term wind direction maximum] OPEL [optoelectronic method]degNoNo0No10min01.01.200430.09.2005 
11h [relative air humidity (h. of air)] SKIN [animal skin]%NoNo0No30min05.08.199409.07.1996 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min10.07.199631.12.2003 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min05.08.199431.12.2003 

 

List of laboratories
Laboratory number 1
pošt. přihrádka 2
Ing. Miroslav  Bitter   
400 11  Ústí nad Labem
Tel: 472 706 053
Fax: 472 706 024
E-mail: bitter@chmi.cz

 

List of data suppliers
Supplier number 1
Pošt. přihrádka 2
Ing. Miroslav  Bitter   
40011  Ústí n/Labem
Tel: 472706053
Fax: 472706024
E-mail: bitter@chmi.cz