HSERA, Serlich

Situation in the year: 2009

Basic data
Code of the measuring programme in the given locality:HSERA
Old ISKO number:1111
Locality: Serlich
Type of measuring programme: Automated measuring program
Measuring networks:National air pollution network, EUROAIRNET, IRIS 
Address
AdministratorČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
Ing. Jiří  Jarka   
50311  Hradec Králové
Tel:495436164
Fax:495436175
E-mail: jarka@chmi.cz
Supplementary data
Target of the measurement programme:Evalution of total level of concentrations beckground
Place description
Stanice je umístěna 150m od Masarykovy boudy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2005 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2005 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2005 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2005 
11O3 [ozone] UVABS [UV-absorption]µg/m3YesYes0Yes1h01.01.2005 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesYes0Yes1h01.01.2005 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2005 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoYes0No10min01.01.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No1h01.01.2005 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoYes0No10min01.01.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No1h01.01.2005 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoYes0No10min01.01.2004 
11WV [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h01.01.2005 
11WV [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min01.01.2004 
11WD [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No1h01.01.2005 
11WD [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No10min01.01.2004 
11WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h01.01.2005 
11WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min01.01.2004 
11WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No1h01.01.2005 
11WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No10min01.01.2005 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2005 
11RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge]mmNoYes0No1h01.01.2005 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No1h01.01.2005 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No10min01.01.2004 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2005 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesNo0No30min21.12.199431.12.2004 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesNo0No30min21.12.199431.12.2004 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesNo0No30min21.12.199431.12.2004 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesNo0No30min21.12.199431.12.2004 
11O3 [ozone] UVABS [UV-absorption]µg/m3YesNo0No30min01.08.199531.12.2004 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesNo0No30min01.01.199631.12.2004 
11SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min09.02.199531.12.1995 
11RAD_A [RAD_A] RAD [dosimeter]uSv/hodNoNo0No30min01.01.200431.12.2004 
11RAD_B [RAD_B] RAD [dosimeter]uSv/hodNoNo0No30min01.01.200431.12.2004 
11RAD_C [RAD_C] RAD [dosimeter]uSV/hodNoNo0No30min01.01.200431.12.2004 
11WV [wind velocity] OPEL [optoelectronic method]m/sNoNo0No30min01.11.199707.11.2001 
11WV [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoNo0No30min08.11.200131.12.2004 
11WD [wind direction] OPEL [optoelectronic method]degNoNo0No30min01.11.199707.11.2001 
11WD [wind direction] U-SONIC [ultrasonic anemometer]degNoNo0No30min08.11.200131.12.2004 
11T [temperature (unspecificated)] PT100 [resistance method]KNoNo0No30min01.11.199731.12.1998 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min01.01.199931.12.2004 
11RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge]mmNoNo0No30min01.01.199931.12.2004 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoNo0No30min01.11.199731.12.2004 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min01.01.199931.12.2004 

 

List of laboratories
Laboratory number 1ČHMÚ - pob.Hradec Králové
Dvorská 410
Ing.  Josef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: antalik@chmi.cz

 

List of data suppliers
Supplier number 1
Dvorská 410
Ing. Jozef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: antalik@chmi.cz