SMBOA, Mlada Boleslav

Situation in the year: 2008

Basic data
Code of the measuring programme in the given locality:SMBOA
Old ISKO number:1437
Locality: Mlada Boleslav
Type of measuring programme: Automated measuring program
Measuring networks:SIS 
Address
AdministratorČHMÚ - pob. Hradec Králové-AIM
Dvorská 410
Ing. Jiří  Jarka   
50311  Hradec Králové
Tel:495436164
Fax:495436175
E-mail: jarka@chmi.cz
Supplementary data
Target of the measurement programme:Evalution of concentration in urban areas, Evaluation of the effect on the population health
Place description
Stanice je umístěna ve sportovním areálu blízko sídliště. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11CO [carbon monoxide] IRABS [IR corel. absorption spectrometry]µg/m3YesYes0Yes1h01.01.2009 
11O3 [ozone] UVABS [UV-absorption]µg/m3YesYes0Yes1h01.01.2004 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesYes0Yes1h01.01.2004 
11WV [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h01.01.2004 
11WV [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min01.01.2004 
11WD [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No1h01.01.2004 
11WD [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No10min01.01.2004 
11WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h01.01.2004 
11WVm [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min01.01.2004 
11WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No1h01.01.2004 
11WDm [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No10min01.01.2004 
11p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoYes0No1h01.01.2004 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2004 
11RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge]mmNoYes0No1h01.01.2004 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No1h01.08.2005 
11GLRD [global radiation] TDM [temperature difference method]W/m2NoYes0No10min01.08.2005 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2004 
21SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesNo0No30min16.04.199831.12.2003 
21NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesNo0No30min16.04.199831.12.2003 
21NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesNo0No30min16.04.199831.12.2003 
21NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesNo0No30min16.04.199831.12.2003 
21O3 [ozone] UVABS [UV-absorption]µg/m3YesNo0No30min01.03.200331.12.2003 
21PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesNo0No30min16.04.199831.12.2003 
21WV [wind velocity] OPEL [optoelectronic method]m/sNoNo0No30min24.02.199931.12.2003 
21WD [wind direction] OPEL [optoelectronic method]degNoNo0No30min24.02.199931.12.2003 
21p [atmospheric pressure] APRESS [atmospheric pressure measurement]hPaNoNo0No30min17.03.199931.12.2003 
21T [temperature (unspecificated)] PT100 [resistance method]KNoNo0No30min16.04.199831.08.1999 
21h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min24.02.199931.12.2003 
21RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge]mmNoNo0No30min01.04.199931.12.2003 
21T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min24.02.199931.12.2003 

 

List of laboratories
Laboratory number 1ČHMÚ - pob.Hradec Králové
Dvorská 410
Ing.  Josef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: antalik@chmi.cz
Laboratory number 2ČHMÚ-CLI TK
Gen.Šišky 942
Ing. Jiří  Novák   
14300  Praha 4 - Libuš
Tel: 244033484
Fax: 241727935
E-mail: novakj@chmi.cz

 

List of data suppliers
Supplier number 1
Dvorská 410
Ing. Jozef  Antalík   
50311  Hradec Králové
Tel: 495436164
Fax: 495436175
E-mail: antalik@chmi.cz