UULK0, Usti n.L.-Kockov

Situation in the year: 2007

Basic data
Code of the measuring programme in the given locality:UULK0
Old ISKO number:1413
Locality: Usti n.L.-Kockov
Type of measuring programme: Heavy metal in PM10
Measuring networks:SIS, Black triangle 
Address
AdministratorČHMÚ-pob. Ústí n. Labem
Pošt.přihrádka 2
Ing. Helena  Plachá   
40011  Ústí nad Labem
Tel:472706057
Fax:472706024
E-mail: placha@chmi.cz
Supplementary data
Target of the measurement programme:Evalution of total level of concentrations beckground
Place description
Jihovýchodní svah nad budovou pobočky (v meteorologické zahrádce), otevřený do podkrušnohorské kotliny s převládajícími severozápadními větry. Odběr : 24hod, analýza kovů každý 5.den.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11 [particles PM10] GRV [gravimetry]µg/m3YesNo0Yes1d/2d01.01.2005 
11 [manganese] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11 [nickel] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11 [copper] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11 [arsenic] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11 [cadmium] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11 [lead] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0Yes1d/2d01.01.2005 
11PM10 [particles PM10] GRV [gravimetry]µg/m3NoNo0No1d/5d05.01.199631.12.2004 
11V [vanadium] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199630.12.2003 
11Cr [chromium] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Mn [manganese] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Fe [iron] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Ni [nickel] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Cu [copper] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11As [arsenic] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Se [selenium] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Cd [cadmium] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Sb [antimony] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Pb [lead] ICP-MS [inductively coupled plasma - mass spectrometry]ng/m3NoNo0No1d/5d05.01.199631.12.2004 
11Pb208/206 [isotopic ratio 208 Pb/206 Pb] ICP-MS [inductively coupled plasma - mass spectrometry]numberNoNo0No1d/5d05.01.199630.12.2003 
11Pb207/206 [isotopic ratio 207 Pb/206Pb] ICP-MS [inductively coupled plasma - mass spectrometry]numberNoNo0No1d/5d05.01.199630.12.2003 

 

List of laboratories
Laboratory number 1ČHMÚ-CLI TK
Gen.Šišky 942
Ing. Jiří  Novák   
14300  Praha 4 - Libuš
Tel: 244033484
Fax: 241727935
E-mail: novakj.chmi.cz

 

List of data suppliers
Supplier number 1
Generála Šišky 942
Mgr. Štěpán  Rychlík   
14300  Praha 4 - Libuš
Tel: 244033482
Fax: 241727935
E-mail: rychliks@chmi.cz