TTROA, Trinec-Kosmos

Situation in the year: 2007

Basic data
Code of the measuring programme in the given locality:TTROA
Old ISKO number:1188
Locality: Trinec-Kosmos
Type of measuring programme: Automated measuring program
Measuring networks:EUROAIRNET 
Address
AdministratorČHMÚ - pob.Ostrava
K Myslivně 3/2182
Mgr. Libor  Černikovský   
70800  Ostrava - Poruba
Tel:596 900 218
Fax:596 910 284
E-mail: cernikov@chmi.cz
Supplementary data
Target of the measurement programme:Evalution of concentration in urban areas
Place description
Stanice umístěna na volném prostranství sídlištního centra. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurement
Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited
Lab.Dod.ComponentMethodUnit ARPar.AcIntervalDate of startDate of end
11 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes1h01.01.2004 
11 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesYes0Yes10min01.01.2004 
11 [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11 [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesYes0Yes1h01.01.2004 
11 [ozone] UVABS [UV-absorption]µg/m3YesYes0Yes1h01.01.2004 
11 [fine particles PM2,5] RADIO [radiometry - beta ray absorption]µg/m3NoYes0Yes1h01.01.2004 
11 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesYes0Yes1h01.01.2004 
11 [benzene] GC-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11 [toluene] GC-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11 [ethylbenzene] GC-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11 [m,p-xylene] GC-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11 [o-xylene] GC-FID [gas chromatography - flame-ionization detection]µg/m3YesYes0Yes1h01.01.2004 
11 [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h16.12.2004 
11 [wind velocity] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min16.12.2004 
11 [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No1h16.12.2004 
11 [wind direction] U-SONIC [ultrasonic anemometer]degNoYes0No10min16.12.2004 
11 [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No1h16.12.2004 
11 [short-term wind velocity maximum] U-SONIC [ultrasonic anemometer]m/sNoYes0No10min16.12.2004 
11 [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No1h16.12.2004 
11 [short-term wind direction maximum] U-SONIC [ultrasonic anemometer]degNoYes0No10min16.12.2004 
11 [relative air humidity (h. of air)] CAP [capacitance sensor]%NoYes0No1h01.01.2004 
11 [temperature 2m above terrain] PT100 [resistance method]KNoYes0No1h01.01.2004 
11SO2 [sulphur dioxide] UVFL [UV-fluorescence]µg/m3YesNo0No30min01.01.199431.12.2003 
11NO [nitrogen monoxide] CHLM [chemiluminescence]µg/m3YesNo0No30min01.01.199431.12.2003 
11NO2 [nitrogen dioxide] CHLM [chemiluminescence]µg/m3YesNo0No30min01.01.199431.12.2003 
11NOx [nitrogen oxides] CHLM [chemiluminescence]µg/m3YesNo0No30min01.01.199431.12.2003 
11O3 [ozone] UVABS [UV-absorption]µg/m3NoNo0No30min01.04.199631.12.2003 
11PM2,5 [fine particles PM2,5] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min31.07.200331.12.2003 
11PM10 [particles PM10] RADIO [radiometry - beta ray absorption]µg/m3YesNo0No30min22.01.199731.12.2003 
11SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption]µg/m3NoNo0No30min01.01.199421.01.1997 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No1h01.01.200415.12.2004 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No30min01.01.199431.12.2003 
11WV [wind velocity] ELMAG [electromagnetic method]m/sNoNo0No10min01.01.200415.12.2004 
11WD [wind direction] ELMAG [electromagnetic method]degNoNo0No1h01.01.200415.12.2004 
11WD [wind direction] ELMAG [electromagnetic method]degNoNo0No30min01.01.199431.12.2003 
11WD [wind direction] ELMAG [electromagnetic method]degNoNo0No10min01.01.200415.12.2004 
11WVm [short-term wind velocity maximum] ELMAG [electromagnetic method]m/sNoNo0No1h01.01.200415.12.2004 
11WVm [short-term wind velocity maximum] ELMAG [electromagnetic method]m/sNoNo0No10min01.01.200415.12.2004 
11WDm [short-term wind direction maximum] ELMAG [electromagnetic method]degNoNo0No1h01.01.200415.12.2004 
11WDm [short-term wind direction maximum] ELMAG [electromagnetic method]degNoNo0No10min01.01.200415.12.2004 
11h [relative air humidity (h. of air)] CAP [capacitance sensor]%NoNo0No30min01.04.199631.12.2003 
11T2m [temperature 2m above terrain] PT100 [resistance method]KNoNo0No30min01.04.199631.12.2003 

 

List of laboratories
Laboratory number 1
K Myslivně 3/2182
Ing. Pavel  Smolík   
708 00  Ostrava - Poruba
Tel: 596 900 228
Fax: 596 910 284
E-mail: ooco_ova@chmi.cz

 

List of data suppliers
Supplier number 1
K Myslivně 3/2182
Mgr. Blanka  Krejčí   
708 00  Ostrava-Poruba
Tel: 596 900 239
Fax: 596 910 284
E-mail: ooco_ova@chmi.cz