HTRMA, Trutnov-Mladeznicka
Situation in the year: 2007
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | HTRMA | ||||||||||
Old ISKO number: | 1504 | ||||||||||
Locality: | Trutnov-Mladeznicka | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | SIS | ||||||||||
Address | |||||||||||
Administrator | ČHMÚ - pob. Hradec Králové-AIM Dvorská 410 Ing. Jiří Jarka 50311 Hradec Králové | Tel:495436164 | |||||||||
Fax:495436175 | |||||||||||
E-mail: jarka@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||||
Place description | |||||||||||
AMS je umístěna v areálu sportovního hřiště ZŠ Trutnov Mládežnická, sídlišt ě Trutnov-Horní Staré Město. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 01.01.2004 | |
1 | 1 | [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.05.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 1h | 01.01.2004 | |
1 | 1 | [global radiation] | TDM [temperature difference method] | W/m2 | No | Yes | 0 | No | 10min | 01.01.2004 | |
1 | 1 | [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 01.01.2004 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | ČHMÚ - pob.Hradec Králové Dvorská 410 Ing. Josef Antalík 50311 Hradec Králové | Tel: 495436164 | |||||||
Fax: 495436175 | |||||||||
E-mail: antalik@chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Dvorská 410 Ing. Jozef Antalík 50311 Hradec Králové | Tel: 495436164 | |||||||
Fax: 495436175 | |||||||||