CCBDA, Ceske Budejovice
Situation in the year: 2007
Basic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | CCBDA | ||||||||||
Old ISKO number: | 1104 | ||||||||||
Locality: | Ceske Budejovice | ||||||||||
Type of measuring programme: | Automated measuring program | ||||||||||
Measuring networks: | EUROAIRNET | ||||||||||
Address | |||||||||||
Administrator | ČHMÚ - pob. Plzeň Mozartova 41 Ing. Tomáš Fory 323 00 Plzeň | Tel:377256641 | |||||||||
Fax:377237444 | |||||||||||
E-mail: fory@chmi.cz | |||||||||||
Supplementary data | |||||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||||
Place description | |||||||||||
Kontejner umístěn na travnatém prostranství mezi městskou zástavbou, asi 300m od pravého břehu Vltavy. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. | |||||||||||
Measurement Lab. = laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement, Ac = accredited | |||||||||||
Lab. | Dod. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | Yes | 10min | 01.01.2004 | |
1 | 1 | [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [fine particles PM2,5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [benzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [toluene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [ethylbenzene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [m,p-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [o-xylene] | GC-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | Yes | 0 | Yes | 1h | 01.01.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.11.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | [wind direction] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.11.2004 | |
1 | 1 | [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | [short-term wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | No | Yes | 0 | No | 10min | 01.11.2004 | |
1 | 1 | [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | [short-term wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | No | Yes | 0 | No | 10min | 01.11.2004 | |
1 | 1 | [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | [temperature 2m above terrain] | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 01.11.2004 | |
1 | 1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 28.03.1994 | 31.12.2003 |
1 | 1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 28.03.1994 | 31.12.2003 |
1 | 1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 28.03.1994 | 31.12.2003 |
1 | 1 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 28.03.1994 | 31.12.2003 |
1 | 1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | No | 30min | 07.09.1994 | 31.12.2003 |
1 | 1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 07.09.1994 | 31.12.2003 |
1 | 1 | PM2,5 [fine particles PM2,5] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 01.05.2003 | 31.12.2003 |
1 | 1 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 24.10.1995 | 31.12.2003 |
1 | 1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 28.03.1994 | 23.10.1995 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 | ČHMÚ - pob. Plzeň Mozartova 41 Ing. Tomáš Fory 323 00 Plzeň | Tel: 377256641 | |||||||
Fax: 377237444 | |||||||||
E-mail: fory@chmi.cz |
List of data suppliers | |||||||||
---|---|---|---|---|---|---|---|---|---|
Supplier number 1 | Mozartova 41 Ing. Jan Hadinger 323 00 Plzeň | Tel: 377256643 | |||||||
Fax: 377237444 | |||||||||
E-mail: hadinger@chmi.cz |