logo ČHMÚ

MJESA, Jesenik

Index Back

Situation in the year: 2005


Basic data
Code of the measuring programme in the given locality: MJESA
Old ISKO number: 1080
Locality: Jesenik
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET, IRIS 
Address
Administrator ČHMÚ - pob.Ostrava
K Myslivně 3/2182
Mgr. Libor  Černikovský   
70800  Ostrava - Poruba
Tel:596 900 218
Fax:596 910 284
E-mail: cernikov@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of total level of concentrations beckground
Place description
V areálu lázní Jeseník, velmi dobrá otevřená lokalita.
Measurement
Lab. = Laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Sup. Component Method Unit A R Par. Interval Date of start Date of end
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 30min 01.06.1996 31.12.2003 
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 1h 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 10min 01.01.2004  
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 1h 01.01.2004  
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 30min 01.08.1996 31.12.2003 
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 25.01.1994 31.12.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 30min 25.01.1994 31.12.2003 
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 25.01.1994 31.12.2003 
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 30min 21.04.1994 31.12.2003 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 21.10.1995 31.12.2003 
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 10min 01.01.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 1h 01.01.2004  
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 1h 01.01.2004  
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No No 0 30min 06.08.1998 31.12.2003 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 30min 25.01.1994 31.12.2003 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 10min 01.01.2004  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 25.01.1994 20.10.1995 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 1h 01.01.2004  
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 30min 08.05.1999 31.12.2003 
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 01.01.2004  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2004  
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 30min 18.01.1995 08.09.2003 
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No No 0 30min 09.09.2003 31.12.2003 
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 01.01.2004  
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2004  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 30min 18.01.1995 08.09.2003 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 01.01.2004  
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No No 0 30min 09.09.2003 31.12.2003 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2004  
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2004  
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 01.01.2004  

 

List of laboratories
Laboratory number 1
K Myslivně 3/2182
Ing. Martin  Nevrla   
708 00  Ostrava - Poruba
Tel: 596 900 228
Fax: 596 910 284
E-mail: nevrla@chmi.cz

 

List of data suppliers
Supplier number 1
K Myslivně 3/2182
Mgr. Blanka  Krejčí   
708 00  Ostrava-Poruba
Tel: 596 900 239
Fax: 596 910 284
E-mail: krejci@chmi.cz

Index Back
Valid XHTML 1.0!