logo ČHMÚ

CHVOA, Hojna Voda

Index Back

Situation in the year: 2005


Basic data
Code of the measuring programme in the given locality: CHVOA
Old ISKO number: 1103
Locality: Hojna Voda
Type of measuring programme: Automated measuring program
Measuring networks: IRIS, EUROAIRNET 
Address
Administrator ČHMÚ - pob. Plzeň
Mozartova 41
Ing. Tomáš  Fory   
323 00  Plzeň
Tel:377256641
Fax:377237444
E-mail: fory@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of total level of concentrations beckground
Place description
Kontejner umístěn na horské louce v sedle mezi Vysokou (1034m.n.m.) a Kuní horou (953m.n.m.) asi 300m od okraje obce Hojná Voda.
Measurement
Lab. = Laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Sup. Component Method Unit A R Par. Interval Date of start Date of end
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 10min 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 1h 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 30min 20.12.1994 31.12.2003 
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No No 0 30min 20.12.1994 31.12.2003 
1 1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % No Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 11.03.1994 31.12.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 30min 11.03.1994 31.12.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 11.03.1994 31.12.2003 
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 30min 01.09.1994 31.12.2003 
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No No 0 30min 20.12.1994 31.12.2003 
1 1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa No Yes 0 1h 01.01.2004  
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 1h 01.01.2004 30.09.2004 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 24.10.1995 31.12.2003 
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2004  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 10min 01.01.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 1h 01.01.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 1h 01.01.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 10min 01.01.2004  
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No No 0 30min 01.06.1998 31.12.2003 
1 1 RAIN [precipitation amount (rain am.)] RAIN [standard rain gauge] mm No Yes 0 1h 01.01.2004  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 10min 01.01.2004  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 30min 11.03.1994 31.12.2003 
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 11.03.1994 23.10.1995 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No No 0 30min 20.12.1994 31.12.2003 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 1h 01.01.2004  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2004  
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No No 0 30min 28.11.2002 31.12.2003 
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 30min 20.12.1994 27.11.2002 
1 1 WD [wind direction] U-SONIC [ultrasonic anemometer] deg No Yes 0 10min 01.01.2004  
1 1 WDm [30 min wind direction maximum] U-SONIC [ultrasonic anemometer] deg No Yes 0 1h 01.01.2004  
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 10min 01.01.2004  
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2004  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 30min 20.12.1994 27.11.2002 
1 1 WV [wind velocity] U-SONIC [ultrasonic anemometer] m/s No No 0 30min 28.11.2002 31.12.2003 
1 1 WVm [30min wind velocity maximum] U-SONIC [ultrasonic anemometer] m/s No Yes 0 1h 01.01.2004  

 

List of laboratories
Laboratory number 1 ČHMÚ - pob. Plzeň
Mozartova 41
Ing. Tomáš  Fory   
323 00  Plzeň
Tel: 377256641
Fax: 377237444
E-mail: fory@chmi.cz

 

List of data suppliers
Supplier number 1
Mozartova 41
Ing. Jan  Hadinger   
323 00  Plzeň
Tel: 377256643
Fax: 377237444
E-mail: hadinger@chmi.cz

Index Back
Valid XHTML 1.0!