Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-05-16 05:10 CEST


Basic data
Code: XMOLA
Old ISKO number: 1472
Locality: Mobilni vuz Libus
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - Libuš AIM
Generála Šišky 942
14000 Praha 4 - Kamýk
Tel.: 244033467
 
E-mail: jan.silhavy@chmi.cz
Target of the measuring programme
unresolved
Cover
air-conditioned mobile container
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 Y A A A R A 10min 2005-09-23
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 95 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03
L1 D1 88 PM 1 [fine particles PM1] - OPEL [optoelectronic method] µg/m³ No Yes 0 N N N N N N 1h 2018-01-01
L1 D1 88 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] µg/m³ Yes Yes 0 Y N A A A A 1h 2018-01-01
L1 D1 88 PM₁₀ [particles PM10] - OPEL [optoelectronic method] µg/m³ Yes Yes 0 Y N A A A A 1h 2018-01-01
L1 D1 111 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 Y N A A R A 1h 2004-08-06
L1 D1 111 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 Y N A A R A 1h 2004-08-06
L1 D1 112 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 1h 2018-01-01
L1 D1 112 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 10min 2018-01-01
L1 D1 112 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N A N N N 1h 2018-01-01
L1 D1 112 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N A N N N 10min 2018-01-01
L1 D1 112 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 1h 2018-01-01
L1 D1 112 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N A N N N 10min 2018-01-01
L1 D1 112 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N A N N N 1h 2018-01-01
L1 D1 112 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N A N N N 10min 2018-01-01
L1 D1 115 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No Yes 0 N N A N N N 1h 2018-01-01
L1 D1 114 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2004-05-03
L1 D1 113 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 1h 2004-05-03
L1 D1 113 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 10min 2005-09-23
L1 D1 114 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-05-03
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 Y A A A R A 1h 2004-05-03 2017-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 88 SPM [suspended particulate matter] - OPEL [optoelectronic method] µg/m³ No No 0 N N N N N N 1h 2019-08-15 2019-09-15
L1 D1 30 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 30 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 30 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 30 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 30 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2004-01-01 2009-12-31
L1 D1 35 WV [wind velocity] - OPEL [optoelectronic method] m/s Yes Yes 0 N N A N N N 1h 2004-05-03 2017-12-31
L1 D1 35 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 35 WV [wind velocity] - OPEL [optoelectronic method] m/s Yes Yes 0 N N A N N N 10min 2005-09-23 2017-12-31
L1 D1 35 WD [wind direction] - OPEL [optoelectronic method] deg Yes Yes 0 N N A N N N 1h 2004-05-03 2017-12-31
L1 D1 35 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 35 WD [wind direction] - OPEL [optoelectronic method] deg Yes Yes 0 N N A N N N 10min 2005-09-23 2017-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s Yes Yes 0 N N A N N N 1h 2008-02-01 2012-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s Yes Yes 0 N N A N N N 10min 2011-12-01 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg Yes Yes 0 N N A N N N 1h 2008-02-01 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg Yes Yes 0 N N A N N N 10min 2011-12-01 2012-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 1h 2004-01-01 2009-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 No No 0 N N N N N N 30min 2003-10-16 2003-12-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 30min 2003-10-16 2003-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 
E-mail: jan.silhavy@chmi.cz